Telecardiology depends on transmitting ECG signals securely, but conventional watermarking that embeds patient metadata directly into the waveform is fragile when the signal is shifted in time. Existing deep watermarking methods for audio avoid that fragility by quantizing the signal, which can blur the high-frequency micro-morphology that matters for diagnosis. In a preprint on arXiv, Kuan-Yu Chen and colleagues propose ECGWmark, a fully convolutional, quantization-free framework that embeds watermarks in a continuous full-resolution latent space and uses a localized frame-level mechanism to withstand severe desynchronization.

To keep the watermark from corrupting clinical content, the authors introduce a differentiable Physiological Loss guided by a clinical classifier. The goal is to preserve diagnostic semantics rather than only signal fidelity. On the MIT-BIH benchmark, the method maintained channel-bit extraction accuracy above 90% under the circular temporal shifts evaluated.

Diagnostic performance under a rigorous inter-patient evaluation was mixed: Class-V sensitivity improved from 71.97% to 76.50%, while Macro-F1 moved from 35.25% to 34.71% and Class-S sensitivity dropped from 8.89% to 1.39%. The authors describe these as mixed class-level effects, suggesting the watermarking scheme is not yet uniformly transparent across all arrhythmia classes.