Medical foundation models are often treated as interchangeable: researchers extract embeddings, train classifiers, and swap in newer models when they appear. A new paper tests that assumption at scale, using more than 750,000 images from 14 datasets, five imaging modalities, and 119 models (18 public plus 101 trained in-house). The authors measure agreement as the fraction of an image's 10 nearest neighbors shared between two models.

Agreement was low. Two public chest X-ray models shared only 9.1% of nearest neighbors on average, barely above the 3.6% shared with a randomly initialized network. In the other four modalities, the maximum overlap was 30%. Convergence depended strongly on the pretraining objective: label-supervised models converged least, with two models differing only in random seed sharing 6.2–10.0% of neighbors, while models trained with self-distillation, masked image modeling, or contrastive learning shared 41.1–80.2%.

The authors also show that the divergence is not insurmountable. A linear mapping between two models' embedding spaces, fitted on 4,096 unlabeled radiographs, transferred classifiers for 14 chest findings with 98.7% of their original AUC. They suggest that before replacing a model, users can check on unlabeled images whether the successor returns the same nearest neighbors. The choice of pretraining objective, they argue, lets developers decide how much convergence they want.